PCI with Novel Sirolimus Eluting Stent

PCI with Novel Sirolimus Eluting Stent: 53 y-old men with Type II diabetes, hypertension, dyslipidemia, family history of CAD. The angiogram showed critical stenosis of Mid and distal RCA as well as Mid LAD – D1 – LCX that was treated with ABLUMINUS DES+. Angiographic and OCT at 15-months revealed good results.

Coronary Angiogram

 

Mid and distal RCA – critical stenoses

  

Mid LAD – D1 – LCX critical stenoses.

LAD – PCI

  

LAD: SC balloon 3.0 mm; Abluminus DES+ 3.0 x 28 mm; Post-dilatation NC balloon 3.0 mm (20 atm) 

D1: POBA with 2.5 SC and NC balloons.

LAD – PCI

 

Final result

RCA – staged PCI

 

Abluminus 2.5 x 18 mm (distal RCA – PDA) Abluminus 3.0 x 26 mm (mid RCA)

Planned LAD – OCT @ 15 months

 

Asymptomatic patient

Planned LAD – OCT @ 15 months

MLA: 4.54 mm2

Max neointimal thickness: 0.62 mm

Neointimal area at the narrowest segment: 1.91 mm2

Strut coverage: 100%