Abluminus NP: Polymer Free Nanocarrier Based Sirolimus Eluting Stent
Abluminus NP - Concept Medical - Developing technologies for drug delivery with a strong emphasis on intellectual property.

Polymer free Sirolimus

Eluting Stent System

Abluminus NP

Deals with the HARD facts with current DES

  • ABLUMINAL COATING - Abluminus NP

    ABLUMINAL COATING

    Drug is coated on the abluminal side only.
    Leading to mono directional drug release & less systemic exposure of drug which leads to faster healing

  • FUSION COATING - Abluminus NP

    FUSION COATING

    Drug is coated on stent as well as exposed parts of balloon & coated on the proximal and distal ends.
    Helps to address the entire disease area of lesion and address focal restenosis and edge restenosis.

  • POLYMER FREE NANO CARRIER DRUG DELIVERY - Abluminus NP

    POLYMER FREE NANO CARRIER DRUG DELIVERY

    Designed for acute as well as sustained drug transfer in arterial wall – leading to less chronic inflammation and improved vascular healing.

  • POLYMER FREE COATING - Abluminus NP

    POLYMER FREE COATING

    Proposed the shorter DAPT which helps to reduced bleeding risk in patients with high bleeding risk

Nanoactive Technology

Advantages of Nanoactive Technology

  • Reduces drug dose

  • Effective drug transfer to the deepest layer of the vessel

  • Protect drug by encapsulation- reduced in-transit drug loss

  • Better in-tissue bioavailability of drug

TECHNICAL SPECIFICATION

DRUG
DrugSirolimus
Drug Dose1.12 µg/mm²
Drug CarrierPhospholipid
Stent
Stent MaterialCobalt Chromium Alloy L605
Strut Thickness73 µm
Strut Width80 µm (hinge) – 120 µm (strut)
Average RecoilLess than 5%
Average ForeshorteningLess than 1% (Zero foreshortening design)
Delivery system
Delivery SystemRX stent delivery system
Nominal Pressure8 bar
Rated Burst Pressure14 bar
Guide Wire Compatibility (max.)0.014’’
Guiding Catheter Compatibility5F
Stent Diameter(mm)2.25, 2.50, 2.75, 3.00, 3.50, 4.00
Stent Length(mm)8, 12, 16, 20, 24, 28, 32, 36, 40

ORDERING INFORMATION

Stent Diameter8 mm*12 mm16 mm20 mm24 mm28 mm32 mm36 mm40 mm
2.25mmEAP22508EAP22512EAP22516EAP22520EAP22524EAP22528EAP22532EAP22536EAP22540
2.50mmEAP25008EAP25012EAP25016EAP25020EAP25024EAP25028EAP25032EAP25036EAP25040
2.75mmEAP27508EAP27512EAP27516EAP27520EAP27524EAP27528EAP27532EAP27536EAP27540
3.00mmEAP30008EAP30012EAP30016EAP30020EAP30024EAP30028EAP30032EAP30036EAP30040
3.50mmEAP35008EAP35012EAP35016EAP35020EAP35024EAP35028EAP35032EAP35036EAP35040
4.00mmEAP40008EAP40012EAP40016EAP40020EAP40024EAP40028EAP40032EAP40036EAP40040

Talk to a representative
Fill out a quick form and our representatives will be in touch.


Sr. NoStudy NameType of StudyTarget PatientsCountryClinical Trials Identifier
Sr. No:  1Study Name:   STARS DAPT Type of Study:  Target Patients:  348Country:  Clinical Trials Identifier:  
“Confidence through evidence”
Get in Touch